Discontinued
TTR310E and TTR330A
About the product
This product is now obsolete and has been replaced by the TTRU3
- Stand-alone or remote-control operation
- Accurately measures ratio, phase deviation and excitation current
- Field upgradeable without compromise to calibration
- Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
- Works in the presence of high interference/high voltage
- Highest ratio measurement (45,000:1); highest accuracy (0.1%)
- Displays % error vs. name plate with pass/fail limits
The TTR300 Series of three-phase transformer turns ratio test sets are designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments. Our leads are specially designed to provide the necessary flexibility needed in cold weather.
The TTR300 Series are ideal for use by power transformer manufacturers. Their unique testing procedures and storage capability allows an operator to set up and test difficult three-phase transformers (with multiple tap changers and bushing CTs) in a fraction of the time than it used to take with other TTRs. This test also includes a pass/fail limit of individual ratios.
Technical specifications
- Automation
- Yes
- Mobility
- Portable
- Single-phase/3-phase capability
- 3-phase
Product documents
Software and firmware updates
Transformer Test Instrument Software Updates for TTR330A
Update Instructions
Please read these instructions before performing the update, you can download them here.
MTO Updater
latest version
Sono stati aggiornati i seguenti componenti:
PowerDB ________________ V11.2.10
MTOTestXP ______________ 2019.12.03.1
Controllo Delta manuale ______________ 2.0.9.51.0
Configurazione dello strumento ______ 1.0.20023.1919
Splash Screen __________ 1.0.21075.830
Configurazione di fabbrica _________ 1.0.21122.850
Megger Update Manager __ 1.0.21165.1032
Consigli
- Megger consiglia di restituire lo strumento ogni anno per una verifica della calibrazione.
- Gli strumenti restituiti per la ricalibrazione vengono aggiornati con le ultime versioni firmware e software.
- La calibrazione di fabbrica certificata è valida per un anno.
Attenzione
Un'installazione errata degli aggiornamenti o aggiornamenti incompleti possono rendere inutilizzabile l'apparecchiatura.
In caso di danni dovuti ad aggiornamenti non corretti, il cliente sarà ritenuto responsabile dei costi di riparazione.
Aggiornamenti software per MTO330A
Scaricare questo file zip, estrarre ed eseguire l'eseguibile.
Hash a 256 bit:
be0628b2014fffeca839036dae42c3d1a6c5c73d79a2e5f2fc6d0716667ef9d3