New
MOM3 Handheld micro-ohmmeter
High Current Capacity
Capable of generating up to 300A, ideal for measuring low resistance in electrical contacts and materials.
Battery Supplied
Powered by batteries, allowing flexible and mobile field testing without relying on external power sources.
Lightweight Design
Weighing just 1.1 kg, the MOM3 is easy to transport, making it perfect for convenient on-site testing.
Auto Range
Auto-ranging feature selects the appropriate range from 1μΩ to 3000 mΩ, ensuring precise measurements.
Wi-Fi Communication
Equipped with Wi-Fi, enabling seamless data transfer to Megger Egil200 for efficient analysis, report and record-keeping.

About the product
The MOM3 handheld 300 A micro-ohmmeter is purpose-built for measuring the resistance of critical electrical components such as circuit breaker contacts, busbar joints, and other high-current links. Its effectiveness in conducting these measurements is achieved using an ultracapacitor, a technology that distinguishes it from conventional capacitors. The size and great interface of the product makes it very practical in use for daily work on site.
The MOM3 micro-ohmmeter includes:
- Ultra Capacitor Technology: The MOM3 employs an ultracapacitor that can store a significant amount of energy compared to standard capacitors. This capability allows it to generate a very high output current during discharge, a crucial requirement for accurately measuring low resistances in high-current components.
- Low Internal Resistance: The ultra capacitor's low internal resistance ensures that the energy it stores is efficiently and effectively discharged, contributing to the micro-ohmmeter's high accuracy when measuring resistance.
Versatile Use: The MOM3 micro-ohmmeter is designed to be highly versatile, making it suitable for use in various settings. It can be employed anywhere to measure low resistance values with a high degree of accuracy, ensuring reliable results.
Related products
Troubleshooting
To maintain the MOM3, keep it clean and store it in a dry, dust-free environment. Regularly check the battery levels and charge them if needed. Avoid exposure to extreme temperatures or moisture to prolong the device's lifespan. Store the MOM3 with battery charged.
First, ensure that the test leads and connections are secure and free from corrosion. Clean the contact points and try re-measuring. If the issue persists, consider recalibrating the device or contact service support for further assistance. Evaluate if object is special and other connection clamps are necessary.
Firmware updates can be done by our authorized service center. If you encounter issues, contact our support team for guidance.
If the battery isn't holding a charge, ensure that it’s fully charged by connecting it to a power source for the recommended time. If the problem continues, the battery may need to be replaced. Contact our service support to order a replacement or for further troubleshooting. Note: The MOM3 has a special battery pack which can only be replaced in our authorized service centers.
While the MOM3 is designed to maintain accuracy, recalibration should be done by a certified service center to ensure precision. If you believe recalibration is necessary, contact our support team to arrange professional calibration services.
If Wi-Fi connectivity issues arise, check that the device is within range of your network and that your network is functioning correctly. Restart the MOM3 and try reconnecting. If the problem persists, consult the user manual or contact customer support for help. MOM3 is made to have Wi-Fi communication with EGIL200.
Test data can be transferred via the Wi-Fi connection to a Megger Egil200 or via USB-C to a computer. Ensure the devices are paired, then follow the prompts on the MOM3 to transfer and save your data. For more detailed instructions, refer to the user manual or reach out to support.
If the device stops working, first check the battery level and recharge the batteries if needed. If the problem isn’t battery-related, reset the device by powering it off and on again. If the issue persists, contact our technical support team for further assistance.
Clean the MOM3 using a soft, dry cloth. Avoid using any liquids or harsh chemicals. Ensure that the test leads and connections are clean and free of debris. Regular cleaning will help maintain the device's accuracy and longevity.
Yes, the MOM3 comes with a 1-year warranty that covers manufacturing defects and component failures under normal use conditions. For full details, please refer to the warranty documentation provided with your device or contact our support team.
Interpreting test results
- Micro-ohm (μΩ) Range: Resistance values measured in micro-ohms (μΩ) typically indicate very low resistance, often associated with high-quality electrical contacts or connections. These low readings are desirable in applications where minimal resistance is required to ensure efficient current flow.
- Milli-ohm (mΩ) Range: When resistance is measured in milli-ohms (mΩ), the values are higher but still relatively low. These readings may indicate slight resistance, which could be acceptable depending on the application. However, higher mΩ values might suggest potential issues like loose connections or corrosion.
- Resistance measurement: The connection points, the surface and the contact pressure and high enough current are of outmost importance when measuring microohm resistance
The MOM3's auto-ranging feature automatically selects the appropriate measurement range for the resistance being tested. This ensures accurate readings across a wide range, from 1 μΩ to 3000 mΩ.
Why Auto-Ranging Matters:
The auto-ranging feature eliminates the guesswork in selecting the right range, reducing the risk of measurement errors. When interpreting results, it's important to trust that the MOM3 has chosen the most accurate range for the given resistance.
The MOM3 is capable of generating up to 300A, making it suitable for testing the resistance of large and critical connections. When interpreting these results, consider the following:
- Consistent Low Resistance: Consistently low resistance across multiple tests indicates a stable and reliable connection, capable of handling high current loads without significant power loss.
- Fluctuating Resistance: If the resistance values fluctuate during repeated tests, this could indicate issues like contact wear, oxidation, or poor connection integrity.
The MOM3's Wi-Fi feature allows for seamless data transfer to the Megger Egil200, enabling further analysis report and record-keeping.
When using this feature:
- Analyze Trends: By transferring data to the Egil200, you can compare test results over time to identify trends in resistance changes. A gradual increase in resistance might suggest degradation in the contact quality.
- Report Generation: The Egil200 can be used to generate detailed reports of the resistance measurements, which are essential for maintenance records and decision-making processes.
- General considerations: Make sure the contact surface is clean and that there is good contact. Measure as close as possible to object you want to measure. Avoid connecting clamps at bolts or screws.
- Temperature Considerations: Resistance can vary with temperature changes. Ensure that measurements are taken in consistent environmental conditions to avoid misinterpretation of results due to temperature effects.
- Multiple Measurements: Conduct multiple measurements to ensure reliability. A single measurement might not reflect the true condition if there are intermittent issues in the contact.
- Comparative Analysis: Compare results against known standards or baseline measurements. This can help determine whether a resistance value is within acceptable limits for the specific application.
Issue | Indicator | Action |
Loose Connections | Higher than expected resistance readings | Tighten and retest |
Corrosion | Gradually increasing resistance over time | Inspect and clean contacts |
Wear and Tear | Fluctuating resistance, especially under load | Replace or repair components |
Inconsistent Results | Varying readings between tests in similar conditions | Check equipment calibration |
Conclusion
Interpreting test results from the MOM3 Micro-ohmmeter is critical for maintaining the reliability and safety of electrical systems. By understanding the significance of the resistance values, leveraging the auto-ranging and high-current capabilities, and utilizing Wi-Fi for advanced analysis, you can ensure that your electrical connections are in optimal condition. Regular monitoring and accurate interpretation of these results will help in preventing potential failures and extending the lifespan of your electrical infrastructure.