Skip to main content

Dissolved Gas Analysis (DGA) Online Monitoring for Transformer Assets

Real‑time hydrogen + acetylene monitoring that prevents failures before they start.

Welcome to the next evolution in transformer protection. Our real‑time DGA monitoring with hydrogen and acetylene detection delivers early fault insight, precise multi‑gas analysis, and continuous diagnostics to ensure safe, reliable transformer performance.

Early Detection for Safer Transformer Operation

Real‑time hydrogen + acetylene monitoring identifies dangerous arcing faults earlier than any co‑based method, preventing catastrophic transformer failures and keeping crews, assets, and communities safer.

Stronger Reliability Through Smarter Monitoring

Two‑gas hydrogen and acetylene monitoring delivers earlier, clearer detection of fault progression, reducing unplanned outages and strengthening fleet‑wide reliability for utilities and industrial operators.

 
Real‑Time Gas Insights for Better Decisions

With real‑time visibility into key fault gases, operators gain deeper insight into transformer health, enabling smarter decisions, accurate risk prioritization, and better long‑term asset planning.

Frequently asked questions

Continually monitoring the trends of these gases over time, together with insights from DGA oil tests, helps identify issues early, diagnose fault types, and extend transformer health through informed maintenance and monitoring. This approach forms part of DGA monitoring solutions for transformer fleets in utilities, supporting consistent condition assessment across multiple assets.

Having a dissolved gas analysis (DGA) power transformer monitoring system in place is crucial for catching these issues when they arise. A developing problem is indicated by a sustained increase in specific fault gases. Normal operating conditions may cause temporary gas increases, but an active fault will produce gases that continue to rise. The type and rate of gas generation reflect the severity of the issue.

Megger's DGA can identify fault types defined in IEEE C57.104-2019 and IEC 60599, including partial discharge, thermal faults, and electrical discharges in your power transformer. These include partial discharge, thermal faults, and discharges, with multi-gas monitoring identifying subtypes such as stray gassing, overheating, carbonization, and catalytic reactions.

No. Online dissolved gas analysis (DGA) monitoring complements offline oil sampling. While online systems provide continuous fault gas trends, offline testing is still required to assess oil quality, including furan content, acidity, and dielectric strength.

Using online DGA monitoring solutions for transformer fleets in utilities allows operators to detect faults early, take corrective action promptly, and maintain reliable transformer performance. This approach helps minimize unplanned outages, extend asset life, and reduce the risk of serious failures.

Yes. Online dissolved gas analysis (DGA) monitoring supports condition-based maintenance by identifying developing faults early, reducing unnecessary inspections and preventing costly unplanned outages. By enabling timely, targeted intervention, Megger’s online DGA monitors help extend transformer life and lower overall maintenance and repair costs.

Online dissolved gas analysis (DGA) monitoring is ideal for critical or high-value transformers where failure would result in significant operational or financial impact. This includes generator step-up (GSU) transformers, heavily loaded transmission and distribution transformers, and units in remote or difficult-to-access locations. Megger’s solutions are designed to operate reliably across a wide range of transformer sizes and applications.

When a DGA alarm is triggered, the gas trends, rates of change, and operating conditions should be reviewed to confirm an active fault. Megger’s online DGA monitoring systems provide the data needed to assess severity and guide next steps, which may include increased monitoring, load adjustments, targeted inspections, or planned maintenance to prevent further damage.

Find Out More

Can’t find what you’re looking for? From basic insulation testers to advanced tools for high-voltage insulation testing, our experts can advise on the best solution for your needs.

Additional resources

Read articles, application notes, and more in-depth content related to dissolved gas analysis (DGA)

Application Note: Online Dissolved Gas Analysis with Megger InsuLogix® G2

A deep dive into dissolved gas analysis (DGA) using the Megger InsuLogix® G2

Read more

Understanding emergency levels in DGA transformer faults

A guide for maintenance teams and completing DGA fault diagnosis.

Read more

Why NASA-Grade Technology Matters for Your Transformer Testing

This white paper details how NASA-grade technology in the InsuLogix® G2 delivers a new standard in oil transformer fault detection.

 

Read more

A Stepwise Approach to Implementing Continuous DGA in Renewable Energy Power Transformers

Ensure grid stability and protect revenue in renewable energy with a stepwise guide to continuous Dissolved Gas Analysis (DGA). Detect faults early, prioritise critical assets, and optimise transformer reliability.

Read More

Secure Your Grid Connection: Continuous DGA for Collector Transformers

Safeguard revenue and grid connection with InsuLogix G2. This robust, continuous DGA solution detects transformer faults early, integrates seamlessly with SCADA, and thrives in harsh renewable environments.

Read More

Megger's advanced DGA monitoring solutions for transformer fleets in utilities provide comprehensive insights into power transformer health:

Early Detection: Industry-leading real-time multi-gas monitoring, delivering 0.5 ppm sensitivity to acetylene alongside continuous hydrogen and moisture monitoring.

Real-Time Risk Assessment: Detect and identify potential issues at their earliest stages, from low-energy partial discharge to critical arcing faults before they develop into major failures, using Megger's online DGA tools for power transformer monitoring.

Strategic Planning: Implement condition-based maintenance with dissolved gas analysis (DGA) for the growing market, avoiding diagnostic limitations.

Cost Control: Integrating online dissolved gas analysis (DGA) system InsuLogix® G2 into your monitoring strategy ensures that risks are mitigated before they compromise your operation, supporting reliable operations in an increasingly competitive dissolved gas analyzer market.