Discontinued
TTR310E and TTR330A

About the product
This product is now obsolete and has been replaced by the TTRU3
- Stand-alone or remote-control operation
- Accurately measures ratio, phase deviation and excitation current
- Field upgradeable without compromise to calibration
- Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
- Works in the presence of high interference/high voltage
- Highest ratio measurement (45,000:1); highest accuracy (0.1%)
- Displays % error vs. name plate with pass/fail limits
The TTR300 Series of three-phase transformer turns ratio test sets are designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments. Our leads are specially designed to provide the necessary flexibility needed in cold weather.
The TTR300 Series are ideal for use by power transformer manufacturers. Their unique testing procedures and storage capability allows an operator to set up and test difficult three-phase transformers (with multiple tap changers and bushing CTs) in a fraction of the time than it used to take with other TTRs. This test also includes a pass/fail limit of individual ratios.
Technical specifications
- Automation
- Yes
- Mobility
- Portable
- Single-phase/3-phase capability
- 3-phase
Product documents
Software and firmware updates
Transformer Test Instrument Software Updates for TTR330A
Update Instructions
Please read these instructions before performing the update, you can download them here.
MTO Updater
latest version
The following components have been updated:
PowerDB ________________ V11.2.10
MTOTestXP ______________ 2019.12.03.1
Delta Manual Control ______________ 2.0.9.51.0
Instrument Config ______ 1.0.20023.1919
Splash Screen __________ 1.0.21075.830
Factory Config _________ 1.0.21122.850
Megger Update Manager __ 1.0.21165.1032
Recommendations
- Megger recommends that you return your instrument annually for calibration verification.
- Any instrument returned for re-calibration will be updated with the latest firmware and software versions.
- Certified Factory Calibration is valid for one year.
Attention
Incorrect installation of updates or incomplete updates may cause the equipment to become unusable.
If damage occurs from improper updates, the customer may be responsible for repair costs.
Software updates for MTO330A
Download this zip file, extract, and run the executable.
256bit Hash:
be0628b2014fffeca839036dae42c3d1a6c5c73d79a2e5f2fc6d0716667ef9d3