Om produkten
- True portable outdoor-ready unit, IP 43
- Very easy to use “turn&click” single rotary knob interface
- Surge/Thump energy 2,000 Joule
- DC testing up to 40 kV, surging/thumping up to 32 kV, burning up to 40 kV
- Prelocation methods: Inductive ARM with Multishot, ICE and DECAY
- Built-in safety circuits for earth connection monitoring (F-Ohm) and touch potential monitoring (F-Voltage)
- Full TDR control of all HV functions
The STX40 is the most powerful and most modern port-able fault location system in the market. It is ideally suited for proof testing, analysing, prelocating and pinpointing of faults on extruded low voltage and medium voltage XLPE- and EPR-insulated cables. With its 40 kV DC source and a potent high frequency burner it is also highly capable and effective on PILC cables as well.
The STX40 is fully automated with motorised HV switches controlled by either the rotary knob or the industry-grade colour touchscreen.
Tekniska specifikationer
- Power source
- Mains
- Test type
- Portable cable fault location
Produktdokument
Mjukvara och firmware
STX Operating Firmware
STX Operating Firmware
latest version
For update packages that contain only one rpm file and therefore only require an update of the operating software, proceed as follows:
1. Copy the zip file to the main directory of a USB flash drive.
2. Unzip the zip file to obtain the rpm file in main directory of the USB flash drive.
3. Insert the USB flash drive into the USB port of the powered-off STX 40.
4. Turn on the STX 40.
Result: The new version of the operating software is automatically detected and installed at start-up.
Do not turn off STX 40 during the update.
MeggerBook
MeggerBook & MeggerBook Lite
MeggerBook & MeggerBook Lite Software
latest version
What’s new in version 4.0.1
Bugfix
- Data export message is now only displayed when the export is completed
- The status of the Online Map checkbox can now be changed
- Fixed an error when saving measurement data sets
- Fixed several design issues and functional inconsistencies
- Fixed several report template errors
- Fixed several problems caused by the template editor's line tool
- Added a mechanism to clean up the segments database table
Improvements
- Extended and improved the rating functions
- Added a pop-up window when saving an empty or already existing cable number
- Added a filter value to the cable detail view
- Improved runtime conversion settings
- Zoom level can now be saved, allowing the user to adjust the curve to the essential point before generating a report
Removed
- The Rating and Result fields are now removed from TDR analyses
- Leakage current values are hidden for measurements where no leakage current is measured
The setup file below is suitable for the installation of both MeggerBook (full version) and MeggerBook Lite (free limited version).
When started with after adding the electronic license key into the installed software, the software starts as MeggerBook full version which allows for easy and comprehensive data evaluation, data archiving, cable management and report creation. A personal quotation for a certain number of licenses can be requested here . The new electronic license key allows for 3 devices to have MeggerBook full version installed on them.
The dongle key licenses from older versions of MeggerBook are not supported with this newer version. Updated electronic license keys can be requested here for previous customers.
Without the required software license key the software starts as MeggerBook Lite which allows for seamless report creation and offers some of the features as the full version while limiting the data storage options as follows:
• Measurements, analyses and reports are not permanently stored in the database
• While cable import and storage are not limited, a maximum of 5 cables can be created using the cable editor of the Lite Edition
At this time, the software can handle the measurement and test data of the following Megger devices:
Test vans: Centrix, Centrix City, Compact City, R30, Variant
Test systems: VLF Sine Wave 45 / 62, VLF CR 40/60, TDS 40/60
TDRs: Teleflex VX(-P), Teleflex SX
Note for test systems VLF Sine Wave 45 and VLF Sine Wave 62:
Data of these test systems can only be imported into the software, if the test systems is equipped with firmware version 3.14 or higher. The latest firmware can be found here (VLF Sine Wave 45) and here(VLF Sine Wave 62).