Om produkten
- Automated 8-terminal/6-winding measurement capability
- Simultaneous winding magnetization
- Tests operation of on-load tap-changers
- Built-in auto-demagnetization feature
- Automatic discharge
- Power DB software (MTO330)
The MTO 300 series delivers full eight-terminal/six-winding resistance measurement capability. It is designed to save time for the user by testing all normal 6 windings without having to disconnect and reconnect leads during testing.
The MTO3xx series also shares the Megger TTR300 series lead set. Users who test both turns ratio and winding resistance can save time and money since only one lead set is needed to connect to the transformer.
Tekniska specifikationer
- Automation
- Yes
- Max output current (DC)
- 10 A
- Single-phase/3-phase capability
- 3-phase
Produktdokument
Mjukvara och firmware
MTO 210/330 Firmware and Software Updates
The Megger Valley Forge, USA factory and select Megger Authorized Service Centers (ASCs) can perform updates. If you do not feel capable of performing updates properly, please contact your nearest Megger sales representative for information on where to return your instrument for updates.
Carefully read all instructions and backup your data before performing any updates.
Only update the firmware or software if you are experiencing difficulty with your instrument or if you have a specific need to do so.
!! WARNING !!
Incorrect installation of updates and incomplete updates may cause an error and make the equipment unusable.
If damage occurs from improper updates, customer is responsible for repair costs.
MTO210 Upgrade Installer
latest version
MTO210
1. Install PowerDB Upgrade (11) [optional]
2. Install Firmware Upgrade:
a. MTO 210 Upgrade Instructions
b. Download MTO 210 Upgrade Installer
MTO330 Brother PocketJet 6 Installer
MTO300/330
1. PowerDB PC Upgrade [Optional]. DO NOT INSTALL THIS ON THE MTO 330
2. Download Brother PocketJet 6 Installer [Accessories]:
a. MTO 330 Brother PocketJet 6 Install Instructions
b. Download MTO 330 Brother PocketJet 6 Installer
Transformer Test Instrument Software Updates for MTO330A
Update Instructions
Please read these instructions before performing the update, you can download them here.
MTO Updater
latest version
The following components have been updated:
PowerDB ________________ V11.2.10
MTOTestXP ______________ 2019.12.03.1
Delta Manual Control ______________ 2.0.9.51.0
Instrument Config ______ 1.0.20023.1919
Splash Screen __________ 1.0.21075.830
Factory Config _________ 1.0.21122.850
Megger Update Manager __ 1.0.21165.1032
Recommendations
- Megger recommends that you return your instrument annually for calibration verification.
- Any instrument returned for re-calibration will be updated with the latest firmware and software versions.
- Certified Factory Calibration is valid for one year.
Attention
Incorrect installation of updates or incomplete updates may cause the equipment to become unusable.
If damage occurs from improper updates, the customer may be responsible for repair costs.
Software updates for MTO330A
Download this zip file, extract, and run the executable.
256bit Hash:
be0628b2014fffeca839036dae42c3d1a6c5c73d79a2e5f2fc6d0716667ef9d3