Training

Transformer Best Practices

Dallas, TX

Megger Best Practices Seminar
Field Testing of Transformers: 

Improved and Emerging Field Testing of Transformers

 

Location:

Megger Dallas Facility

4545 West Davis Street

Dalls, TX 75211

 

Transformer field testing is still today the main activity performed all over the world to determine the condition of a transformer and it is based on the traditional tests: Power factor, turns ratio, winding resistance, excitation current and leakage reactance. All these tests have been in use for many years, although technology and years of investigation have brought to each of these innovations that have made them more accurate, effective, and efficient. 

Megger’s Best Practices Seminar is designed to present the latest advancements in transformer testing and better assessment of transformer health conditions. The seminar is divided into two main sections: dielectric assessment and winding assessment. 

In the diagnostic of the dielectric, we will cover the basics of power factor testing to cover the new horizons of this traditional testing: 1 Hz and Individual Temperature Correction (ITC). Next, we will see how moisture content inside a transformer can be determined, as well as the value of the conductivity of the oil using the Dielectric Frequency Response technique. 

The winding assessment section starts presenting a new dawn of the step-up technique for turns ratio testing as well as the benefits of true three-phase testing. Then winding resistance is discussed to illustrate how the test is much more efficient with dual excitation and the benefits of adaptive demagnetization. To complete the winding assessment section, we will discuss high voltage excitation current as well as leakage reactance and the ability to determine the efficiency of the transformer.

Leveraging that the majority of the above-mentioned tests are also practiced on instrument transformers, we are also presenting the field challenges to test current transformers and the mitigation techniques.

 

This event is free to attend

 

Note: If the registration form below produces the message "A technical error occurred" please try again later.

Registration Form

Agenda

8:15am
to
8:25am
Welcome, housekeeping and introductions
8:25am
to
8:45am
Transformer fundamentals: Theoretical session on the working of a transformer and the insulation characteristics with importance of insulation assessment.
8:45am
to
9:30am
Power factor testing evolution: Power factor testing basics overview with a focus on Power factor testing on transformer and the significant tools developed to complement the test.
9:30am
to
10:15am
Advanced dielectric assessment DFR 1Hz ITC: Going beyond line frequency power factor testing on transformer and discussing the advanced tests which provide in-depth details on the dielectric conditioning of the transformer and other power assets.
10:15am
to
10:30am
Break
10:30am
to
11:15am
Winding Resistance & Turns Ratio emerging technologies: Discussion on recent developments to conventional Winding resistance and Transformers Turns Ratio Tests
11:15am
to
12:00pm
Voltage Excitation Current and Leakage reactance Test: Transformer core is an important aspect when it comes to minimizing losses and improving efficiency, focus on the basics and result analysis of the Excitation Current test and Leakage reactance test
1:00pm
to
2:15pm
Hands on Demonstration - TTRU1, TTRU3 & TAU3, MTO
2:15pm
to
2:30pm
Break
2:30pm
to
4:00pm
Optional: Hands on Demonstration - IDAX, Delta 4000, TRAX (TDX, STX)